43.8V Series For 12cells 38.4V LiFePO4 Battery Charger | ||||||||||||||||||||||
■ Features | |||||||||||||||||||||||
·Universal AC input / Full range | |||||||||||||||||||||||
·Plastic or metal case optional | |||||||||||||||||||||||
·Cooling by free air convection | |||||||||||||||||||||||
·MTBF:30000 hours | |||||||||||||||||||||||
·Provide 3 years warranty | |||||||||||||||||||||||
·Install fuses on both ends of the Input and Output for double safety | |||||||||||||||||||||||
·Protections:Short circuit / Over load / Over voltage / Over temperature | |||||||||||||||||||||||
·Meet CEC,DoE Level VI,Energy star,ErP stage 2,CoC Tier 2,NRCan & GEMS | |||||||||||||||||||||||
·Certification:UL,ETL,CUL,GS,CE,BS,SAA,KC,PSE,CB,FCC,EMC,RoHS,REACH | |||||||||||||||||||||||
SPECIFICATION | |||||||||||||||||||||||
OUTPUT | MODEL NO. |
FY4401000
|
FY4402000
|
FY4403000
|
FY4404000
|
FY4405000
|
FY4406000
|
FY4407000
|
FY44090000
|
||||||||||||||
OUTPUT VOLTAGE | 24-43.8V | 24-43.8V | 24-43.8V | 24-43.8V | 24-43.8V | 24-43.8V | 24-43.8V | 24-43.8V | |||||||||||||||
OUTPUT CURRENT | 1A | 2A | 3A | 4A | 4.5A | 6A | 7A | 9A | |||||||||||||||
OUTPUT POWER | 43.8W | 87.6W | 131.4W | 175.2W | 197.1W | 262.8W | 306.6W | 394.2W | |||||||||||||||
PFC (MIN.) | 0.6 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | |||||||||||||||
RIPPLE & NOISE (max.) | 440mVp-p | 440mVp-p | 440mVp-p | 440mVp-p | 440mVp-p | 440mVp-p | 440mVp-p | 440mVp-p | |||||||||||||||
INPUT | INPUT VOLTAGE RANGE | 100 ~ 240VAC | |||||||||||||||||||||
FREQUENCY RANGE | 50 / 60Hz | ||||||||||||||||||||||
INPUT POWER | NO LOAD: 0.5W MAX AT INPUT 100-240VAC 50/60Hz . LOADING : 450W MAX , AT RATED OUTPUT . | ||||||||||||||||||||||
TEMPERATURE RISING | CASE 65 ℃ MAX .℃ FOR RATED OUTPUT | ||||||||||||||||||||||
EFFICIENCY (MIN) | 88% | ||||||||||||||||||||||
DIELECTRIC WITHSTAND TEST | 5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND | ||||||||||||||||||||||
PROTECTION | OVER LOAD | THE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT | |||||||||||||||||||||
SHORT CIRCUIT: | CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY | ||||||||||||||||||||||
ENVIRONMENT | WORKING TEMP RANGE | THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM -29 ℃ TO + 45 ℃ | |||||||||||||||||||||
STORAGE TEMPERATURE | THE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM -40 ℃ TO + 75 ℃ | ||||||||||||||||||||||
RESISTANCE TO HEAT | WHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3℃ FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM | ||||||||||||||||||||||
RESISTANCE TO MOISTURE | THE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT 40 ± 2 ℃ AT 90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER. | ||||||||||||||||||||||
SAFETY & EMC | SAFETY STANDARDS | UL60950 EN60335 | |||||||||||||||||||||
EMI | CISPR22 CLASS | ||||||||||||||||||||||
INSULATION | B | ||||||||||||||||||||||
OTHERS | MTBF | THEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25 ℃ | |||||||||||||||||||||
CONNECTOR | PLUG | 5521, 5525, RCA, XLR, XT60, M16, C14. | |||||||||||||||||||||
CABLE | UL2464 18# 1M length |