120W Series Switching power supply |
■ Features |
·Universal AC input / Full range |
·Plastic or metal case optional |
·Cooling by free air convection |
·MTBF:30000 hours |
·Provide 3 years warranty |
·Install fuses on both ends of the Input and Output for double safety |
·Protections:Short circuit / Over load / Over voltage / Over temperature |
·Meet CEC,DoE Level VI,Energy star,ErP stage 2,CoC Tier 2,NRCan & GEMS |
·Certification:UL,ETL,CUL,GS,CE,BS,SAA,KC,PSE,CB,FCC,EMC,RoHS,REACH |
SPECIFICATION |
OUTPUT |
MODEL NO. |
FY1207000
|
FY1208000
|
FY2404000
|
FY2405000
|
FY3603000
|
FY5102000
|
FY4802000
|
|
OUTPUT VOLTAGE |
12V |
12V |
24V |
24V |
36V |
51V |
48V |
|
OUTPUT CURRENT |
7A |
8A |
4A |
5A |
3A |
2A |
2A |
|
OUTPUT POWER |
84W |
96W |
96W |
120W |
108W |
102W |
96W |
|
PFC (MIN.) |
0.9 |
0.9 |
0.9 |
0.9 |
0.9 |
0.9 |
0.9 |
|
RIPPLE & NOISE (max.) |
120mVp-p |
120mVp-p |
240mVp-p |
240mVp-p |
360mVp-p |
510mVp-p |
480mVp-p |
|
INPUT |
INPUT VOLTAGE RANGE |
100 ~ 240VAC |
FREQUENCY RANGE |
50 / 60Hz |
INPUT POWER |
NO LOAD: 0.5W MAX AT INPUT 100-240VAC 50/60Hz . LOADING : 130W MAX , AT RATED OUTPUT . |
TEMPERATURE RISING |
CASE 65℃ MAX .℃ FOR RATED OUTPUT |
EFFICIENCY (MIN) |
90% |
DIELECTRIC WITHSTAND TEST |
5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND |
PROTECTION |
OVER LOAD |
THE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT |
SHORT CIRCUIT: |
CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY |
ENVIRONMENT |
WORKING TEMP RANGE |
THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM -29 ℃ TO + 45 ℃ |
STORAGE TEMPERATURE |
THE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM -40 ℃ TO + 75 ℃ |
RESISTANCE TO HEAT |
WHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3℃ FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM. |
|
RESISTANCE TO MOISTURE |
THE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT 40 ± 2 ℃ AT 90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER. |
SAFETY & EMC |
SAFETY STANDARDS |
UL60950 EN60950 EN61558 |
EMI |
CISPR22 CLASS |
INSULATION |
B |
OTHERS |
MTBF |
THEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25 ℃ |
DIMENSION |
154*60*36mm (L*W*H) |
PACKING |
450g/pcs; 42pcs/20Kg/CARTON(53*37*21cm) |
CONNECTOR |
PLUG |
5.5*2.1, 5.5*2.5,4pin |
CABLE |
UL2464 18# 1M length |