14.6V Series For 12V Lead-Acid Battery Charger |
■ Features |
·Universal AC input / Full range |
·Plastic or metal case optional |
·Cooling by free air convection |
·MTBF:30000 hours |
·Provide 3 years warranty |
·Install fuses on both ends of the Input and Output for double safety |
·Protections:Short circuit / Over load / Over voltage / Over temperature |
·Meet CEC,DoE Level VI,Energy star,ErP stage 2,CoC Tier 2,NRCan & GEMS |
·Certification:UL,ETL,CUL,GS,CE,BS,SAA,KC,PSE,CB,FCC,EMC,RoHS,REACH |
SPECIFICATION |
OUTPUT |
MODEL NO. |
FY1501000
|
FY1502000
|
FY1503000
|
FY1504000
|
FY1505000
|
FY1506000
|
FY1507000
|
FY1509900
|
OUTPUT VOLTAGE |
9-14.6V |
9-14.6V |
9-14.6V |
9-14.6V |
9-14.6V |
9-14.6V |
9-14.6V |
9-14.6V |
OUTPUT CURRENT |
1A |
2A |
3A |
4A |
5A |
6A |
7A |
10A |
OUTPUT POWER |
14.6W |
29.2W |
43.8W |
58.4W |
73W |
87.6W |
102.2W |
146W |
PFC (MIN.) |
0.6 |
0.6 |
0.6 |
0.6 |
0.9 |
0.9 |
0.9 |
0.9 |
RIPPLE & NOISE (max.) |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
INPUT |
INPUT VOLTAGE RANGE |
100 ~ 240VAC |
FREQUENCY RANGE |
50 / 60Hz |
INPUT POWER |
NO LOAD: 0.5W MAX AT INPUT 100-240VAC 50/60Hz . LOADING : 150W MAX , AT RATED OUTPUT . |
TEMPERATURE RISING |
CASE 65 ℃ MAX .℃ FOR RATED OUTPUT |
EFFICIENCY (MIN) |
88% |
DIELECTRIC WITHSTAND TEST |
5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND |
PROTECTION |
OVER LOAD |
THE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT |
SHORT CIRCUIT: |
CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY |
ENVIRONMENT |
WORKING TEMP RANGE |
THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM -29 ℃ TO + 45 ℃ |
STORAGE TEMPERATURE |
THE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM -40 ℃ TO + 75 ℃ |
RESISTANCE TO HEAT |
WHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3℃ FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM |
|
RESISTANCE TO MOISTURE |
THE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT 40 ± 2 ℃ AT 90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER. |
SAFETY & EMC |
SAFETY STANDARDS |
UL60950 EN60335 |
EMI |
CISPR22 CLASS |
INSULATION |
B |
OTHERS |
MTBF |
THEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25 ℃ |
CONNECTOR |
PLUG |
5521, 5525, RCA, XLR, XT60, M16, C14. |
CABLE |
UL2464 18# 1M length |